For standing events, calculate 1 square meter per person; for banquets, 1.5 square meters. Therefore, the choice of seating has the greatest impact on space requirements. It determines a room's capacity more than the type of event does. Including a dance floor and a buffer, most parties and events end up between 1 and 2 square meters per guest.
The table shows the calculator's guideline values per seating type and how many guests fit into 100 m² accordingly.
The guest count includes a 10% buffer for walkways, pillars, and alcoves. The final column shows the calculated value based on assembly venue regulations and is not a recommendation.
Common seating arrangements and their practical space requirements:
The reason these values vary so much is that some planning aids include stages, catering, and aisles, while others only count the chair. This is why tent planners often suggest 2.5–3 square meters per person for a banquet. Our values cover the seating areas including the aisles between them, and everything else is added as a separate area in the calculator.
At a cocktail party or a walking dinner, standing and sitting are mixed. For this, select "standing reception" in the calculator, add the buffet, and enter the high tables as additional space. More space is not automatically better, as a half-empty hall can be just as detrimental to the atmosphere as an overcrowded room.
In Germany, the Model Assembly Venue Ordinance calculates 1 visitor per m² at tables and 2 visitors per m² for row seating. For standing room, it requires at least 2 people per m². These values apply to rooms with a capacity of more than 200 visitors. The calculation is based on the net area for visitors; stages and technical equipment are not included.
Ultimately, the number specified in the venue's approved seating plan is binding. This capacity must not be exceeded, and the plan should be posted at the main entrance. In Germany, the federal states have incorporated the model ordinance into their own regulations. In Austria, each federal state regulates this itself. According to its event safety ordinance, Styria calculates 3 people per m² for standing room and 1 person per m² at tables.
The maximum number of people also depends on escape routes. For every 200 people, an emergency exit must be 120 cm wide, and narrow doors can limit a room's capacity. These figures are not for comfort; they are used by authorities to determine exit and escape route requirements. If you want to host a great party, plan for more space per person—which is exactly what the values in the table above are for.
To determine the size of the dance floor for an event with dancing, calculate about 0.2 m² per guest. This is based on two rules of thumb: at peak times, about 40% of guests will be dancing simultaneously, and each person needs about 0.5 m². For 100 guests, that equals 20 m², or a square with 4.5 m sides.
For couple dances like the waltz or discofox, you need significantly more space, often cited as 3–4 m² per couple. However, the area will still accommodate the wedding's opening dance, as only the bride and groom are on the floor at the start.
Practical tip: A dance floor that is too large will feel empty, which can quickly dampen the mood. It is better to plan it compactly and place it right next to the DJ. If it is tucked away in a corner or a separate room, it often stays empty.
The PA system wattage calculator shows how much power your sound system needs for your guests and your venue.
For a DJ with two speakers, we recommend planning for 3 x 2 m, or 6 m². A photo booth with a backdrop and room to pose requires about 3 x 3 m, which is 9 m². Both are best placed against a wall near a power outlet and never in front of an emergency exit.
Based on caterers' experience, a buffet line can serve up to 120 guests. Including the table, the aisle in front, and space for staff behind it, our calculator estimates 12 m² per line. You can enter bars, stages, or lounge areas as additional space.
If you are renting equipment for your celebration, it is best to include its footprint in your planning right from the start. Renty offers appropriately sized sound systems with no deposit and all-risk insurance, available for pickup or with on-site setup.
The examples show typical events and come directly from the calculator, with a 10% buffer already included. In addition to the number of guests, three factors play a role: the seating arrangement, the buffer for walkways, and everything else placed in the room. For 40 people at round tables, 66 m² is sufficient; for a standing event, 44 m² is enough.
These values apply to the usable area. If the description only states the total area, you will need a larger room.

Subtract everything that guests cannot use: pillars, fixed counters, and alcoves. After this deduction, you are left with the net area you should use for your calculations. Event location offers often only state the total area, and the usable space is significantly less.
When searching for an event location, the calculator works both ways. If you know the number of guests, it provides the necessary size. If you have an offer with a fixed area, it shows the capacity. Ultimately, the seating plan is what counts for your decision, and it is best to clarify any open questions in advance. The guide to event planning shows how location and technology are connected in event planning.
You can easily calculate the size of the room: length times width equals the square footage. A 12 x 15 m room is 180 m². Divide L-shaped rooms into rectangles and add them together. When viewing the space, also pay attention to the ceiling. In low-ceilinged rooms, it quickly gets stuffy with many guests; in that case, only more space or good ventilation will help.
Tables and technical equipment have no place on escape routes. In assembly venues, escape routes must be at least 120 cm wide; in rooms with up to 200 seats, 90 cm is sufficient. The regulations specify 150 cm between tables, and the path from any seat to the exit must be no more than 30 m.
For rows of chairs, each seat must be at least 50 cm wide, with 40 cm of free space between rows. There can be a maximum of ten chairs on either side of an aisle. If you are setting up chairs just for the event, they must be securely connected in rows. There are exceptions for restaurants.

From experience: We see four mistakes repeated time and again when planning with our clients. Use these tips to avoid them.
The calculator prevents the first three mistakes if you enter the DJ, photo booth, and buffet and calculate using the usable area. For birthdays, there is a separate checklist for the venue.
For outdoor and tent events, each person needs just as much space as they would indoors, so the guidelines in the table apply here as well. The rules are different, however. For outdoor events, the ordinance only applies to gatherings of more than 1,000 visitors. Tents are considered temporary structures and require their own permit once they reach a certain size.
Dance floors and bars require the same amount of space in a tent as they do in a hall. Plan for extra space outside for paths between the tent, bar, and toilets. If it rains, everyone will move into the tent, so it should be large enough for all guests.
With a 10% buffer, about 90 guests fit into 100 m² standing, 129 in rows of chairs, and 60 at round tables. According to the assembly venue ordinance, the mathematical capacity is 200 people standing or in rows and 100 at tables.
Mathematically, 2 people standing, but one is comfortable. According to a technical report by the vfdb, people can still move freely at up to 2 people per m². From 6 people per m² upwards, the report speaks of critical density, such as can occur in front of stages at concerts.
Standing still without much movement, a person needs about 0.5 m². This corresponds to the 2 people per m² specified in the ordinance. For a standing reception with drinks, conversation, and movement, plan for 1 m² per person.
With a 10% buffer, 55 m² is sufficient for 50 people standing, 66 m² for a long banquet table, and 83 m² for round tables. The calculator above automatically accounts for a DJ or buffet.
The model ordinance provides for 3 women's toilets, 1 men's toilet, and 2 urinals for up to 100 visitors. For every additional 100 visitors, 1.2 women's toilets, 0.4 men's toilets, and 0.8 urinals are added mathematically. The result is rounded up.
There is no fixed upper limit per m² for parties at home. In a venue, the number of people permitted for the room applies even to private parties. At home, noise levels and quiet hours are more likely to set the limits than the floor space.
Use these free calculators and generators to plan the rest of your event, from the technical requirements to the tournament schedule.
Wir haben dir eine Mail geschickt, bitte bestätige sie um den Rabattcode zu erhalten.